Annexin V-AF 647 Apoptosis Detection Kit, with Propidium Iodide
貨號 | 數量 | 價格 | 交貨時間 | 購買此產品 |
---|---|---|---|---|
14172 |
10 assays
|
– | 21 天 | |
24172 |
50 assays
|
$148 | 21 天 |
Annexin V (or Annexin A5) is a member of the phospholipid-binding annexin family of intracellular proteins. In flow cytometry and fluorescent microscopy, Annexin V is commonly used to detect apoptotic cells by its ability to specifically bind to phosphatidylserine (PS) in a calcium-dependent manner. The method was first reported by Koopman et al. (1994) [1].
In healthy cells, PS is normally retained in the inner leaflet of the plasma membrane. The early stage of apoptosis is accompanied by a loss of membrane phospholipid asymmetry, resulting in the exposure of PS at the cell's surface. In conjunction with vital dyes such as propidium iodide (PI), fluorochrome-labeled Annexin V can distinguish between healthy (Annexin−PI−), apoptotic (Annexin+PI−), and necrotic (Annexin+PI+) cells [2].
The ready-to-use kit contains all necessary reagents to label apoptotic cells with Annexin V-AF 647 conjugate and PI.
AF 647 is a bright, far-red-emitting fluorescent dye with high fluorescence quantum yield and photostability. The spectrum of AF 647 is far from the green-yellow wavelengths, which makes it indispensable for labeling cells with high autofluorescence. The absorption and emission maxima of AF 647 are at 655 and 680 nm, respectively.
PI is a membrane-impermeable DNA stain, making it useful for differentiating necrotic, apoptotic, and healthy cells based on membrane integrity. After DNA binding, the dye emits in the orange-red channel. Its absorption max. is at 535 nm, the emission max. is at 617 nm.
[1] Koopman G. et al. Annexin V for flow cytometric detection of phosphatidylserine expression on B cells undergoing apoptosis. Blood. 1994. 84(5). P.1415-1420.
[2] Martin S.J. et al. Early redistribution of plasma membrane phosphatidylserine is a general feature of apoptosis regardless of the initiating stimulus: inhibition by overexpression of Bcl-2 and Abl. J Exp Med. 1995. 182(5). P.1545-1556.
顧客還購買了這個產品
Mitochondrial Membrane Potential Apoptosis Kit, with LumiTracker® Mito Red CMXRos & Annexin V-AF 488
The ready-to-use kit for assaying two key indicators of apoptosis: the externalization of phosphatidylserine and alterations in mitochondrial membrane potential.立即在線獲取免費快遞服務
Annexin V-AF 488細胞凋亡檢測試劑盒
即用型試劑盒,可使用Annexin V-AF 488和碘化丙啶染料標記凋亡和壞死細胞。Annexin V-AF 488 結合物 (Annexin V-AF 488 conjugate)
即用型試劑盒,可使用Annexin V-AF 488 結合物和碘化丙啶標記凋亡和壞死細胞。储存条件: | |
MSDS: | 下載 |
储存时间(月: | 9 |